AvCount AvCount Particle Counter - ASTM D7619; IP 565; DEF STAN 91-91 & 91-86
ASTM D7619, IP 565 - Test methods for sizing and counting particles in light and middle distillate fuels by automatic particle counter.
- Fully automatic operation
- Particle size 4μm to >70μm
- Cumulative & distributive particle numbers
- ISO4406: 1999 codes
- Uses "Straight from the Bottle" samples
- Precise and reliable results
- Laboratory or portable field use
- Calibrated in accordance with ISO 1117
AvCount is a new laser based particle counter for checking and maintaining the quality of aviation jet fuel throughout the distribution network.
Fuel types include aviation turbine oils, biofuels and biofuel blends, heating oil, gas oil, diesel - automotive and marine, gasoline and kerosine.
For Aviation Jet Fuel:
IP 565
Determination of the level of cleanliness of aviation
turbine fuel - Portable automatic particle counter method
DEF STAN 91-91
Seta ‘AvCount’ Particle Counter IP 565 is now included in DEF STAN 91-91 Aviation Jet Fuel Specification, Issue 6 for Certifying Jet A-1. Click here for information about IP 565 in DEF STAN 91-91.
Maintaining Fuel Quality in the supply and distribution systems is a major concern. The potential for particulate (dirt) contamination is high, particularly from:
- Refinery Processing Materials
- Corrosion & Rust in Pipes and Tanks
- Airborne Solids
- Degraded & Damaged Hoses and Filters
- Microbiological Growth
The avcount particle analyser is a rugged and portable instrument specifically designed for testing the particulate content of aviation jet fuel for particles ranging from 4μm to >70μm diameter.
The avcount uses the light obscuration principle, where the fluid under test is passed through a cell comprising a laser and a calibrated sensor. Particles in the fluid cast a shadow onto the sensor, which determines the area / diameter and number of particles in the sample.
Sampling and measurement is simple; fuel is drawn from a sample container or directly from the supply line. Avcount has a 10 bar standard pressure rating or can sample up to 315 bar line pressure using the optional pressure reducing system. An integral pump automatically draws the sample through an internal measuring chamber, removing the need for an external sampling pump.
Avcount is fully automatic once the particle count test sequence is started. The instrument flushes the cell with sample prior to commencing the measurements. A precise volume of sample is then analysed. The flushing / sample analysing sequences are automatically repeated in accordance with the selected test method.
Results are displayed on the LCD screen in real time and printed out on the integral printer as the test progresses. The results are shown for 6 particle size bands in Particles/ml and ISO Code. Results can be saved to memory for trend analysis of samples, printed out on the integral printer or downloaded to a PC or external printer.
The "Log and Show" software option allows data to be downloaded from the instrument to a PC in different formats and allows the instrument to be fuly controlled and configured from any Windows interface.
Request a quote and to find your local representative
Our products
AvCount Laser Particle Counter ASTM D7619, IP 565, DEF STAN 91-91
AvCount2 Laser Particle Counter ASTM D7619, IP 565, DEF STAN 91-91
H2S Analyser ASTM D7621, IP 570, ISO 8217
FIJI- FAME in Jet Instrument for IP 583 Rapid Screening method
EvoChrom HPLC aromatics in diesel fuel and biodiesel fuel
EvoChrom HPLC aromatics in aviation fuels
Evocrom HPLC SDA in jet fuel and diesel fuel